CC2- POST QUIZ- LFT, AUTOMATION
Identification:
1.__________Air bubbles_________________________________
The part of the reagent test pack that
acts as cuvette.
2._________peristaltic pump______________________________ Give one common part present in both CFA and
FIA.
3.__________fluorocarbon_________________________________This
substance coats the inner parts of the automated machines to prevent
contamination
4.__________peristaltic pump______________________________
It suctions the sample or reagents into
the system.
5.__________glucose, lipids, enzymes, LFT tests, RFT
tests_______Name one substance tested in RA.
6.__________sampling device_____________________________
It consists of a sample turn table and a moving articulated aspiration tube.
7.___________debubbler_________________________________Its
aim is to remove the introduced air bubbles before the liquid stream reaches
the flow cell of the detector.
8._____________automatic clinical analyzer_________________Transcribe
ACA.
9._____________pack header____________________________
Which part of the DuPont ACA carries a binary code?
10.____________2 uL to 1,000 uL_________________________Range
of volume of sample in centrifugal analyzers.
11._____________0.3 to 1 mm___________________________What
is the usual length of the tubings in FIA.
Fill in the needed
items:
Parameter
|
SFA
|
FIA
|
SAMPLE INSERTION
|
12. suction
|
13.injection
|
SAMPLE VOLUME
|
14. 0.2-2 mL
|
15. 10-400 uL
|
REAGENT CONSUMPTION (INDICATE IF MORE OR LESS)
|
16. more
|
17. less
|
WASHING CYCLE
|
18. essential
|
19. non-essential
|
NUMBER OF SAMPLES
|
20. less than 80 samples/hr.
|
21.less than 500 samples/hr.
|
PRECISION
|
22. 1-2 %
|
23. 1-2%
|
INDICATE WITH AN
ARROW WHETHER THE SUBSTANCE IS INCREASED OR INCREASED OR N (NORMAL)
DISEASE/CONDITION
|
B1
|
B2
|
TB
|
HDN
|
25. N
|
26.INCREASE
|
|
PREHEPATIC JAUNDICE
|
27.INCREASE
|
28. N
|
29.INCREASE
|
POSTHEPATIC
|
30. N
|
31.INCREASE
|
|
ROTOR’S
|
33 N
|
34.INCREASE
|
35.INCREASE
|
Identification:
1.______________spreading layer or scavenger layer_________
The layer that removes interfering substances.
2.______________centrifugal analyzer_____________________
The heart of the system is the rotor.
3.______________continuous segmented stream____________It
prevents contamination by using air bubbles.
4.______________continuous flow injection________________
It prevents contamination by using small lateral tubings.
5.______________DuPont ACA ___________________________
The heart of the system is the reagent test pack.
6.______________sampling device_________________________
It consists of a sample turn table and a moving articulated aspiration tube.
7.______________debubbler______________________________Its
aim is to remove the introduced air bubbles before the liquid stream reaches
the flow cell of the detector.
8.______________segmented flow analyzer_________________Transcribe
SFA.
9.______________pack header_____________________________
Which part of the DuPont ACA carries a binary code?
10._____________dry slide technology______________________This
automated method measures reflected light.
11.______________0.3 to 1 mm____________________________What
is the usual length of the tubings in your answer to no. 4?
Fill in the needed
items:
Parameter
|
SFA
|
FIA
|
SAMPLE VOLUME
|
12. 0.2-2 mL
|
13. 10-400 uL
|
WAY OF PREVENTING CONTAMINATION
|
14. air bubbles
|
15. small lateral tubings
|
REAGENT CONSUMPTION (INDICATE IF MORE OR LESS)
|
16. more
|
17. less
|
PRECISION
|
18. 1-2%
|
19. 1-2%
|
NUMBER OF SAMPLES
|
20. less than 80 samples/hr.
|
|
WASHING CYCLE
|
22. essential
|
23. nonessential
|
INDICATE WITH AN
ARROW WHETHER THE SUBSTANCE IS INCREASED OR INCREASED OR N (NORMAL)
DISEASE/CONDITION
|
B1
|
B2
|
TB
|
GILBERT’S SYNDROME
|
24.INCREASE
|
25. N
|
26.INCREASE
|
CARCINOMA OF THE BILIARY TREE
|
27. N
|
29.INCREASE
|
|
HEPATITIS A
|
30.INCREASE
|
31.INCREASE
|
32.INCREASE
|
CRIGLER NAJJAR SYNDROME
|
33.INCREASE
|
34.INCREASE
|